GE LOGIQ P6 DTRX64 Board 5252321/5212114 Medical Ultrasonic Ultrasound Machine

  • 1
  • 2

Brand Name : GE

Model Number : LOGIQ P6

MOQ : 1

Price : Negotiable

Payment Terms : T/T, Western Union

Delivery Time : 2-4 work days

Packaging Details : Neutral Package

System : GE LOGIQ P6

Part Number : 5252321/5212114

Item : Ultrasound Board/Part

Time Require : 2-5 Days

Category : Repair/Exchange Ultrasound Board

Before Delivery : tested images&videos will be shared

Warranty : 60 days after fixed

Contact Now

GE Logiq P6 DTRX64 Board

1.Discrimination:DTRX64 Board
2.Pre-owned original one ,in excellent condition
3.We provide 60 days warranty

Various GE/Siemens/Toshiba/Hitachi/ Biosound/Medison ultrasonic boards are within our repair/ maintenance range.

GE LOGIQ P6 DTRX64 Board 5252321/5212114 Medical Ultrasonic Ultrasound Machine

Other ultrasound parts related that we can offer:

Brand System Description Part Number
GE Logiq P5 APS Power Supply 5140505/5166108/5329667
GE Logiq P5 CPU mainboard 5168431
GE Logiq P5 SYSCONPM 5177848-3
GE Logiq P6 CPU Mainboard
GE Logiq P6 PST Power Supply 5245004/5244555
GE Logiq P6 SYSCONML 5252326-3
GE Logiq S7/Logiq S8 CPS Power supply 6626600 R02/5413249-3
GE Logiq S7 BF128 transmitting board 5392446
GE Logiq S7 GFS board 5371196
GE Logiq S8 BF192 Beamformer 5357234-2

Knowledge Point

About GE Logiq P6 DTRX64 Board

1. Basic functions and components of DTRX64 Board
DTRX64 Board is a key component in GE Logiq P6 ultrasonic diagnostic equipment, mainly responsible for the transmission and reception of ultrasonic signals. It is the main board in ultrasonic diagnostic equipment that receives sound waves and converts them into images, and plays a vital role in the formation of ultrasonic images. DTRX64 Board connects and controls the probe to transmit ultrasonic waves through the probe connection board. The echo after the ultrasonic wave scans the organ or lesion is converted into an electrical signal through the probe, which is received and processed by DTRX64 Board.

2. Fault manifestations and troubleshooting of DTRX64 Board
In GE Logiq P6 ultrasonic diagnostic equipment, the failure of DTRX64 Board may cause a variety of problems, such as image loss, image interference, etc. The following are some specific fault manifestations and troubleshooting methods:

Image loss:
Fault manifestation: Black strip echo loss appears in the scanning area or there is no signal in the entire image area.
Troubleshooting method: First check whether the probe is intact, including the probe crystal, cable and interface; then check the DTRX64 Board and its related connection lines to confirm whether there is any damage or poor contact; finally, try to swap the DTRX64 Board in different positions for testing to determine the faulty board.
Image interference:
Fault manifestation: interference signals such as clutter and stripes appear in the image.
Troubleshooting method: First eliminate the electromagnetic interference outside the device; then check whether the probe generates interference, such as whether the probe appearance is intact and whether the shielding is good; finally, check whether the DTRX64 Board and its related boards (such as the SYSCONML board) are faulty, and try to replace the board for testing.

3. Maintenance and replacement of DTRX64 Board
In order to ensure the normal operation of the GE Logiq P6 ultrasonic diagnostic equipment, it is very necessary to perform regular maintenance and inspection of the DTRX64 Board. This includes cleaning the board surface, checking whether the connection lines are firm, and performing regular performance tests. When the DTRX64 Board fails, contact the equipment manufacturer or a professional maintenance organization in time for replacement. During the replacement process, the following points should be noted:

Confirm the faulty board: Before replacement, you must ensure that the faulty board has been accurately identified to avoid unnecessary replacement and waste.
Safe operation: During the replacement process, you must follow the equipment's safe operating procedures to ensure the safety of the operator.
Correct installation: When installing a new board, you must follow the requirements of the equipment manual to ensure that the board is installed correctly and firmly.
Test verification: After the replacement is completed, performance testing and verification must be performed to ensure that the equipment resumes normal operation.

We provide professional ultrasonic plate repair services.10+years of professional maintenance service team.

If you need any product, please feel free to contact us.

Various Ultrasound Systems that we served

GE Ultrasound System
LOGIQ P5, LOGIQ P6, LOGIQ S7, LOGIQ S8, VOLUSON 730, VOLUSON S8, VOLUSON P8, VOLUSON S6, VOLUSON S20, VOLUSON P8, VOLUSON E10, VIVID E9, LOGIQ BOOK, LOGIQ 5, LOGIQ 7, LOGIQ 9, LOGIQ E9, LOGIQ F6, LOGIQ F8, VIVID I, VIVID Q, VOLUSON I, VOLUSON E, VIVID S5, VIVID 3, VIVID 7...

Hitachi-Aloka Ultrasound System
F31, F37, SSD-3500, SSD-3500, SSD-4000, SSD-5000, ALPHA 5, ALPHA 6, ALPHA 7, ALPHA 10, PROSOUND F75, HI VISION AVIUS, HI VISION PREIRUS, EUB-5500, EUB-6500, EUB-7500, EUB-8500, Arietta 60, Arietta 70, Ascendus...

Siemens Ultrasound System
S2000,S3000,SC2000,X300,P500,OXana,Juniper,Omini...


Product Tags:

Medical Ultrasonic DTRX64 Board

      

GE LOGIQ P6 DTRX64 Board

      

5252321/5212114 DTRX64 Board

      
Wholesale GE LOGIQ P6 DTRX64 Board 5252321/5212114 Medical Ultrasonic Ultrasound Machine from china suppliers

GE LOGIQ P6 DTRX64 Board 5252321/5212114 Medical Ultrasonic Ultrasound Machine Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Guangzhou Rongtao Medical Tech LTD.
*Subject:
*Message:
Characters Remaining: (0/3000)